NTA 8220: the standard behind Scope 10

StandardsReading time: 4 minutesUpdated: September 2026
Google rating: 5,0 out of 10 reviews★★★★★Rated by our clients

NTA 8220 is younger and less known than NEN 3140, but it determines what your insurer asks of you. The difference lies in the question it poses: not is this safe to work with, but could this cause a fire.

A standard that looks at fire

NTA 8220 describes a method for assessing electrical equipment for fire risk. It was developed because insurers wanted an inspection aimed specifically at the causes of electrical fire, and none existed.

A classical inspection checks whether protective measures work. This standard checks whether heat is being generated where it should not be, whether equipment is used outside its specifications, and whether the surroundings of the installation are arranged in a fire prone way.

What is different during the inspection

A Scope 10 inspection therefore examines things a Scope 8 leaves out of view.

  • Mandatory thermography under representative load
  • The surroundings of the board: is combustible material stored against it?
  • Usage behaviour: overloaded distribution blocks, damaged leads, temporary fixes that became permanent
  • The technical condition and placement of distribution and control panels

Why load matters so much

Thermography only works when current is flowing. A connection slowly working loose only becomes warm under load. That is why we plan the measurement for a moment when your installation is operating normally, not during a quiet Saturday morning.

It is also why a Scope 10 inspection can be carried out without stopping production: most of it happens precisely while everything runs.

What you gain from it

Apart from your insurer's requirement, this inspection usually delivers the most in practice. The defects it uncovers are often exactly the things you cannot see yourself and that eventually lead to downtime or fire. Tightening a connection is cheap; a night without production is not.

In practice this subject belongs with our Tailored inspection en Energy storage inspection. There you can read how we work and what exactly is checked, or you can request a quote without obligation aan.

Further reading: the difference between Scope 8 and Scope 10, the difference between Scope 10 and Scope 12, what is NTA 8220?.

Tip from the inspector

If you are unsure which inspection you need, send us the passage from your policy that mentions electrical work or inspection. We read those daily and can see within minutes what your situation requires.

Frequently asked questions

Is NTA 8220 a law?

No, it is a Dutch Technical Agreement, so an agreed method. It gains force because insurers include it in their policy conditions.

Can a Scope 10 inspection be done without thermography?

No. Thermography is a mandatory element within NTA 8220. Without it the report is incomplete and therefore invalid.

Must my installation be under load during the measurement?

Yes, otherwise a thermal image says very little. We agree in advance when your installation is representatively loaded.

Prefer personal advice?

Call us or ask your question through the form. We are happy to think along about what your situation needs.

Get in touch Request a quote

Want your installation inspected by a SCIOS certified body?

Request a quote without obligation, or call us to discuss the scope of the inspection.

Request a quote More information
Make a request